Pressure Systems 9022 Manuel d'utilisateur Page 22

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 194
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 21
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual
www.PressureSystems.com
2 - 5
NOTE: After closing the TCP/IP connection to the module, the host must wait 10
seconds before re-connecting.
to assign to those devices. This application is free of charge and capable of running as a background
program on Windows
®
95/98/2000 and NT machines. It may be downloaded from the PSI internet
home page, www.PressureSystems.com.
Use of Static or Dynamic IP settings may be selected through the Set Operating Options ('w')
command. If you are unsure how your module is configured, check the Tx LED during module
power-up. If it begins to blink periodically after the module power-up, your instrument is configured
for the Dynamic IP assignment protocol. (Tx LED remains OFF in static IP configuration.) If
configured for Dynamic IP assignment, a dynamic server must be configured on the network to
return an IP address to the module. Without an IP address, the host will be unable to open a TCP/IP
or UDP/IP connection to the module.
Vue de la page 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 193 194

Commentaires sur ces manuels

Pas de commentaire